TRA Air Cooled Split Marine Air Conditioning Unit

Product code TRA03 TRA05 TRA08 TRA10 TRA15 TRA20
Nominal Cooling Load (kW) 10.5 17.5 28.0 35.0 56.0 70.0
Nominal Air Flow (Evaporating) (m³/h) 1530 2550 4075 5100 7725 10200
Plenium Discharge Fan Motor Rating (kW) 0.37 0.55 1.10 1.50 2.12 3.0
Comp. Motor Power (kW) 3.55 5.48 9.79 10.94 19.58 21.88
Nominal Condensing Load (kW) 14.42 21.42 33.24 47.44 77.78 94.88
Nominal Air Flow (Condensing) (m³/h) 6624 9360 14400 21600 28080 37440
Condenser Fan motor rating (kW) 2@0.37 2@0.55 2@0.75 3@0.58 3@0.75 4@0.75
Electric Heating (Optional) 1x4.5 2x4.5 2x9.0 3x9.0 3x9.0 4x9.0
Internal - Unit Dimensions - H (mm) 1300 1600 1800 1800 2000 2100
Internal - Unit Dimensions - W (mm) 900 900 1200 1250 1400 1800
Internal - Unit Dimensions - D (mm) 450 550 650 650 850 850
Internal - Unit Dimensions - P (mm) 120 180 230 230 300 330
Internal - Unit Weight (kg) 178 219 284 328 501 594
External - Unit Dimensions - H (mm) 1380 1400 1420 1400 1420 1420
External - Unit Dimensions - W (mm) 1200 1400 1700 2400 2600 3200
External - Unit Dimensions - D (mm) 700 800 900 900 1100 1100
External - Unit Weight (kg) 154 200 253 290 409 528

Nominal duties are based on air entering @ 35°Cdb @ 50% RH utilising R407c with ambient air at 40°C


View R134a version
  • Nominal cooling loads 10.5 kW to 70.0 kW
  • Air Cooled
  • Refrigerant R407c / R448A / R449A
  • TR02 to TR10 fitted with hermetic compressor
  • TR15 & TR20 fitted with semi-hermetic compressors with capacity control
  • Internal section
    • Electro coated mild steel casing with powder coated paint finish RAL 9018 (Grey)
    • Removable panels for access and maintenance
    • Quick release grille for air filter cleaning and replacement
  • External Section
    • Electro coated mild steel casing with 2 component Polyurethane paint finish RAL 9018 (Grey)
    • Condenser coil with Cu tubes and Cu fins
  • Electrical supply 380V 3ph 50Hz or 440V 3ph 60Hz
  • Other options available
    • Colour to suit operating environment
    • Fan pressures to suit application
    • Electric heating
    • Non-standard electric supply
    • Refrigerant R134a
    • Horizontal air flow external section
    • Interconnecting piping cable
    • See separate data sheet for water cooled units