VK Self Contained Marine Air Conditioning Unit
Product code | VK12 | VK18 | VK24 | VK36 |
Nominal Cooling Load (kW) | 3.50 | 5.25 | 7.00 | 10.50 |
Nominal Air Flow - low (m³/h) | 400 | 500 | 800 | 1200 |
Nominal Air Flow - high (m³/h) | 500 | 675 | 1000 | 1500 |
Fan Motor Rating (kW) | 0.037 | 0.045 | 0.074 | 0.111 |
Fan Motor Current (A) | 0.85 | 1.10 | 1.70 | 2.55 |
Comp. Motor Power (kW) | 1.76 | 2.30 | 4.40 | 4.39 |
Comp. Motor Current (A) | 2.88 | 3.90 | 5.39 | 7.00 |
Nominal Sea Water qty. (m³/h) | 0.43 | 1.3 | 2.74 | 5.46 |
Nominal Fresh Water qty. (m³/h) | 1.22 | 0.59 | 1.62 | 2.18 |
Unit Dimensions - H (mm) | 450 | 550 | 550 | 650 |
Unit Dimensions - W (mm) | 760 | 760 | 1060 | 1360 |
Unit Dimensions - D (mm) | 380 | 380 | 380 | 400 |
Unit Weight (kg) | 85 | 95 | 130 | 160 |
Electric Heating (Optional) (kW) | 1.5 | 1.5 | 3.0 | 4.5 |
Nominal duties are based on air entering @ 25°Cdb @ 50% RH utilising R407c with sea water @ 32°C or fresh water @ 36°C
View R134a version
- Nominal cooling loads 3.5 kW, 5.25 kW, 7.00 kW and 10.50 kW
- Sea water or Fresh water cooled through shell and tube condenser
- Refrigerant R407C, R448A or R449AC
- Electro coated mild steel casing with powder coated paint finish RAL 9018 (Grey)
- Removable top and side panels for access and maintenance
- Quick release grille for air filter cleaning and replacement
- Units supplied factory pre-charged only requiring suitable water and electrical connections
- Electrical supply
- 220V 1ph 50/60Hz
- 380V 3ph 50Hz
- 440V 3ph 60Hz
- Other options available
- Colour to suit operating environment
- Electric heating
- Refrigerant R134a (see separate datasheet)
- Availability of R404A on request
- Fresh water plate heat exchanger
- See separate data sheet for air cooled VK units